United Kingdom
Design of control and protection system (typical schemes) for 132kV side.
Design of control and protection system (typical schemes) for 275kV and 132kV.
Protection and control circuit diagrams for 4 bays on 275kV side, System monitoring circuit diagrams, Control and protection cubicle design, Interface and wiring diagrams for commissioning purposes (generation of material lists, cable schedules and termination lists) on individual 4 bays on 275kV side.
As built documentation 4 bays for 132kV side.
As built documentation 3 bays for 275kV side
3D modeling and Conceptual Design (Primary and Secondary).
3D modeling and Conceptual Design (Primary and Secondary).
3D modeling and Conceptual Design (Primary and Secondary).
The Netherlands
3D modeling and primary design for additional transformer connection. Existing situation is done from point cloud. Total three transformers.
3D modelig and primary design for additional transformer connection. Existing situation is done from point cloud. Total three transformers.
Primary design – Layout, Sections, 3D modeling.
Design of control and protection system for 380kV.
Design of control and protection system for 380kV and 150kV.
Primary design – Layout, Sections, 3D modeling.
Primary design – Layout, Sections, 3D modeling.
Primary design – Layout, Sections, 3D modeling.
USA
Design of control and protection system and replacement of existing HV panels with new one.
Design of control and protection system and replacement of existing HV panels with new one.
3D modeling and conceptual design.
Design for replacement of protection relays included relay setting programing (50GE relays – C60, C30, B30, L90, F35).
3D modeling and Conceptual Design (Primary and Secondary).
3D modeling and Conceptual Design (Primary and Secondary).
3D modeling and Conceptual Design (Primary and Secondary).
Extension of existing 13.8kV yard (Primary, Secondary, and 3D modeling from point cloud).
Kingdom of Saudi Arabia
Conceptual design, technical specification of equipment (HV-MV-LV swg, motors up to 9MW, ATT, Cooling Water system, Luboil system, UPS, power compensation, earthing system, Lighting system, Primary equipment, Power cables, Control cables, Line traps, Gantry, tray system, Power Tr, Aux. Tr) and price calculation for 4x132kV, 6×13.8kV and 12×0.4kV stations for water pipeline systems.
As built documentation for PSA2 and PSA3 substations.
Belgium
Design of protection system included new interface, protection link (differential) for 150kV OHL. Design of protection system for 150kV transformer
Design of protection system included new interface, protection link (differential) for 150kV OHL. Design of protection system for 150kV transformer.
Design of protection system included new interface, protection link (differential) and cubicles for 150kV OHL.
Design of protection system included new interface, protection link (differential) and cubicles for 150kV OHL.
Design of control and protection cubicles for diesel generators, Wiring diagrams, Cubicle design for 2 generators.
Design of generator protection replacement schematic drawings.
Design of control and protection cubicles for diesel generators, Wiring diagrams, Cubicle design for 3 generators.
Design of control and protection cubicles for diesel generators, Wiring diagrams, Cubicle design for 3 generators.
Japan
3D modeling and visualization.